AS-i 3.0 Command Interface Commands of the Command Interface
Subject to reasonable modifications due to technical advances Id.-No.: 102875 Issue date - 3.12.2007 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen Tel. +49/711/7597-0, Fax +49/711/753316
71
4.7.6 Integrated AS-i sensors: Availability
(Function: 04
16
)
List of the integrated slaves according to profile S-1.1 whose input data bits D2
("Availability") are deleted.
For creating this list, CDI and IDI are used only. Integrated AS-i slaves which are
projected but not existing therefore are not entered here.
Request
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
17E
16
2T O circuit
304
16
Response (if O ≡ 0)
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
17E
16
2T result
376543210
……
63130292827262524
Response (if O ≡ 1)
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
17E
16
2T result
301234567
……
62425262728293031
Kommentare zu diesen Handbüchern