Technical data for safety switch CES-AP-C01-CH
Parameter Value Unit
min. typ. max.
Housing material PBT V0 GF30
Dimensions According to EN 60947-5-2
Weight 0.4 kg
Ambient temperature at U
B
= DC 24 V - 20 - + 55
°C
Storage temperature - 25 - + 70
Degree of protection
acc. to EN IEC 60529
IP 67
Safety class III
Degree of contamination 3
Installation position Any
Connection M12 plug connector, 8-pin or 5-pin
Operating voltage U
B
(reverse polar-
ity protected, regulated, residual
ripple < 5%)
24 ± 15% (PELV) V DC
For the approval according to
the following applies
Operation only with UL Class 2 power supply, or equivalent
measures
Current consumption 50 mA
Switching load according to
DC 24 V, class 2
External fuse (operating voltage) 0.25 - 8 A
Safety outputs OA/OB Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U(OA)/U(OB)
1)
HIGH
U(OA)
U
B
-1.5 - U
B
V DC
HIGH
U(OB)
LOW
U(OA)/U(OB) 0 1
Switching current per safety output 1 - 400 mA
Utilization category
according to EN IEC 60947-5-2
DC-13 24 V 400 mA
Caution: outputs must be protected with a free-wheeling diode in
case of inductive loads.
Off-state current
according to EN IEC 60947-5-2
(OA/OB)
2)
- - 0.25 mA
Monitoring output DIA
1)
p-switching, short circuit-proof
- Output voltage 0.8 x U
B
- U
B
V DC
- Max. load - - 200 mA
Rated insulation voltage U
i
- - 300
3)
V
Rated impulse withstand voltage U
imp
- - 1.5 kV
Resilience to vibration In acc. with EN IEC 60947-5-2
Switching frequency - - 1 Hz
Repeat accuracy R
acc. to EN IEC 60947-5-2
10 %
EMC protection requirements according to EN IEC 60947-5-3 and EN IEC 61326-3-1
Reliability values acc. to EN ISO 13849-1
Category 4
Performance Level PL e
PFH
d
2.1 x 10
-9
/ h
Mission time 20 years
1) Values at a switching current of 50 mA without taking into account the cable length.
2) Maximum current at an output in switched-off state.
3) Tested by employers’ liability insurance association up to 75 V.