Seite 1 - CES-AP-C01-CH (Multicode)

More than safety.Operating InstructionsNon-Contact Safety SwitchCES-AP-C01-CH (Multicode)

Seite 2 - Contents

Operating Instructions Safety Switch CES-AP-C01-CH10Notes on operation with safe control systemsPlease observe the following requirements for connecti

Seite 3 - Correct use

Operating Instructions Safety Switch CES-AP-C01-CH11Safety in case of faults Ì The operating voltage UB is reverse polarity protected. Ì The contacts

Seite 4

Operating Instructions Safety Switch CES-AP-C01-CH12Requirements for connection cablesCaution!Risk of damage to equipment or malfunctions as a result

Seite 5 - General safety instructions

Operating Instructions Safety Switch CES-AP-C01-CH13ConnectionNote:The connection examples show the 8-pin version. The 5-pin version is connected anal

Seite 6 - Function

Operating Instructions Safety Switch CES-AP-C01-CH14Warning!In the event of a fault: Loss of the safety function due to incorrect connection. Ì To ens

Seite 7

Operating Instructions Safety Switch CES-AP-C01-CH15SetupLED indicatorsLED Color State SignificanceSTATEgreenillumi-natedNormal operation: Door closedfl

Seite 8 - Mounting

Operating Instructions Safety Switch CES-AP-C01-CH16System status tableOperating modeActuator/door posi-tionSafety outputs OA and OBLED indicator, out

Seite 9 - Electrical connection

Operating Instructions Safety Switch CES-AP-C01-CH17Technical dataNote:If a product data sheet is included with the product, the information on the da

Seite 10

Operating Instructions Safety Switch CES-AP-C01-CH18Typical system timesReady delay: After switching on, the unit carries out a self-test for 500 ms.

Seite 11 - Safety in case of faults

Operating Instructions Safety Switch CES-AP-C01-CH19Technical data for actuator CES-A-BBAParameter Value Unitmin. typ. max.Housing material Fortron, r

Seite 12 - 8-pin 5-pin

Operating Instructions Safety Switch CES-AP-C01-CH2ContentsAbout this document 3Correct use 3Possible combinations for CES components 4Exclusion of

Seite 13 - Connection

Operating Instructions Safety Switch CES-AP-C01-CH20Switching distancesOperating distance for center offset m = 0(only in combination with CES-A-BBA a

Seite 14 - M12 plug-connector

Operating Instructions Safety Switch CES-AP-C01-CH21Technical data for actuator CES-A-BPAParameter Value Unitmin. typ. max.Housing material PBTDimensi

Seite 15 - Functional check

Operating Instructions Safety Switch CES-AP-C01-CH22Switching distancesOperating distance for center offset m = 0(only in conjunction with actuator CE

Seite 16 - System status table

Operating Instructions Safety Switch CES-AP-C01-CH23Technical data for actuator CES-A-BRNParameter Value Unitmin. typ. max.Housing material PPSDimensi

Seite 17

Operating Instructions Safety Switch CES-AP-C01-CH24Switching distancesOperating distance for center offset m = 0(only in combination with actuator CE

Seite 18 - Dimension drawing

Operating Instructions Safety Switch CES-AP-C01-CH25Ordering information and accessoriesDesignation Version Order No.CES-AP-C01-CH-SA-100250 Plug conn

Seite 19

Operating Instructions Safety Switch CES-AP-C01-CH26ServiceIf service support is required, please contact:EUCHNER GmbH + Co. KGKohlhammerstraße 16D-70

Seite 20 - Typical operating distance

Operating Instructions Safety Switch CES-AP-C01-CH27Declaration of conformity

Seite 21

Operating Instructions Safety Switch CES-AP-C01-CH28

Seite 22

Operating Instructions Safety Switch CES-AP-C01-CH29

Seite 23 - Active face

Operating Instructions Safety Switch CES-AP-C01-CH3About this documentThis document is valid for all safety switches CES-AP-C01-CH with version number

Seite 24

More than safety.Euchner GmbH + Co. KGKohlhammerstraße 16D-70771 [email protected]:103895-08-10/13Title: Ope

Seite 25 - Inspection and service

Operating Instructions Safety Switch CES-AP-C01-CH4Possible combinations for CES componentsSafety switchesActuatorCES-A-BBA071840CES-A-BPA098775CES-A-

Seite 26

Operating Instructions Safety Switch CES-AP-C01-CH5General safety instructionsAs the unique actuator codes are not evaluated, the CES-AP-C01-CH versio

Seite 27 - Declaration of conformity

Operating Instructions Safety Switch CES-AP-C01-CH6FunctionThe device complies with the following safety requirements: Ì Category 4, PLe according to

Seite 28

Operating Instructions Safety Switch CES-AP-C01-CH7Changing the approach directionCaution!Risk of damage to equipment as a result of trapped cables. Ì

Seite 29

Operating Instructions Safety Switch CES-AP-C01-CH8MountingImportant! Ì From the assured switch-off distance Sar, the safety outputs are safely shut d

Seite 30 - More than safety

Operating Instructions Safety Switch CES-AP-C01-CH9Electrical connectionWarning!In the event of a fault: Loss of the safety function due to incorrect