Manual EKS Electronic-Key Adapter Profibus-DP
4.2 Technical data, Electronic-Key adapter
Attention!
All the electrical connections must either be isolated from the mains supply by a safety transformer
according to EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent
isolation measures.
General parameters Value Unit
min. typ. max.
Housing Plastic (PA 6 GF30 gray)
Degree of protection according to EN 60529 IP 67 in installed condition
Ambient temperature at UB = 24 V DC 0 + 55 °C
Mounting cut-out acc. to DIN 43700 33 x 68 mm
Connection for power supply Plug-in screw terminal, 3-pole,
max. conductor cross-section 1.5 mm², tightening torque
0.22 Nm
Operating voltage UB
(regulated, residual ripple < 5 %)
20 24 28 DC V
Current consumption 150 mA
Interface, data transfer
Interface to host control
RS485
(address selectable via DIP switch)
Address range 0 ... 126
Transfer protocol Profibus-DP according to EN 50170
Data transfer rate 9.6/19.2/45.45/93.75/187.5/500 kbps
1.5/3/6/12 Mbps
Connection for Profibus-DP Sub-D 9-pin
Cable length max.
100 ... 1200
according to Profibus-DP, depending on data transfer rate
m
LED display
Green: "Ready" (in operation)
Yellow: "Electronic key active" *
Red: "Error"
Parameters for the outputs LA and LB (version EKS FSA only)
Power supply for load U (LA, LB) 24 30 V
Switching current per output 1 50 mA
Number of actuations of the overload
protection
100
Output voltage high for U (LA, LB) U x 0.9 U V
Resistance in switched-on state 35 Ohm
Capacitance per output 2 nF
Additional capacitive load per output 1 µF
Utilization category according to AC-12
EN IEC 60947-5-2 AC-15
DC-12
DC-13
50 mA / 24 V
Difference time between the outputs**
(LB first)
200 ms
Connection screw terminals, 2 x 2-pole 0.14 1.5 mm²
* The LED lights up yellow if there is a functional Electronic-Key in the Electronic-Key adapter.
** If access on the Profibus interface takes place during the insertion or removal of the Electronic-Key,
the difference time can be more than 200 ms.
092009-03-10/07 Subject to technical modifications Page 12/36