Manual EKS Electronic-Key Adapter Ethernet
4.4 DIP switch settings
The device has three DIP switches (S1, S2, S3).
DIP switch Function
S1
(4-fold)
S1.1 … S1.4; write and read settings
S2
(8-fold)
S2.1 … S2.8; setting of a fixed DNS name (required only for special applications)
S3
(4-fold)
S3.1 …S3.4; settings for network connection and service
Information!
The settings are only applied when the power supply is switched on.
4.4.1 DIP switch S1
DIP
switch
Function Factory setting
S1.1 ON = write protection for read/write Electronic-Key OFF
S1.2 No function OFF
S1.3 No function OFF
S1.4 No function OFF
Information!
It is imperative that all DIP switches without a function (S1.2, S1.3 and S1.4) are set to OFF! In this
way problems with any functions added in the future will be avoided.
4.4.2 DIP switch S2
DNS
name
LSB
S2.1
S2.2
S2.3
S2.4
S2.5
S2.6
S2.7
MSB
S2.8
EKS000 OFF OFF OFF OFF OFF OFF OFF OFF
EKS001 ON OFF OFF OFF OFF OFF OFF OFF
EKS002 OFF ON OFF OFF OFF OFF OFF OFF
EKS003 ON ON OFF OFF OFF OFF OFF OFF
… … … … … … … … …
EKS254 OFF ON ON ON ON ON ON ON
EKS255 ON ON ON ON ON ON ON ON
Information!
All DIP switches S2 are relevant only in conjunction with the Siemens SINUMERIK DHCP address
assignment (see section 6.1.1.3 Operation in the Siemens system network).
Page 14/40 Subject to technical modifications 100420-02-01/09